Find, fix and prove energy savings across your portfolio
Your buildings already raise dozens of energy alerts a month. The energy optimization agent turns them into a short list priced in euros, makes the fixes it can, routes the rest, and verifies every saving against a weather-normalized baseline.
More alerts don’t mean more savings
Monitoring agents are good at spotting waste. But a list of alarms doesn’t tell an owner which ones are worth acting on, who should act, or whether the fix actually worked.
Alarms aren’t priced
A clogged filter and an idle economizer arrive with the same urgency. One costs a little; the other runs your chillers all spring.
Fixes stall between teams
Some changes can be made from the BMS in seconds. Others need a technician or a capex decision. Without routing, both wait.
Savings go unproven
If a saving can’t be shown against a fair baseline, finance won’t count it and auditors won’t accept it.
How it works
One loop: find, rank, act, verify
Find
Collects findings from the free cooling, ventilation, district heating, chiller, setpoint and filter agents, plus an ASHRAE Level I screening of meter data.
Rank
Prices each finding in euros per year from energy use, your tariffs, demand charges and district heating penalties. Duplicates merge; the biggest wins rise to the top.
Act
Applies what the control agents can change, after your approval. Opens service objects for technicians and hands capex measures to the ECM packager.
Verify
Measures each fix against a weather- and occupancy-normalized baseline and reports the verified saving to ISO 50001 and the EU Taxonomy tracker.
Interactive demo
Watch one office building go through the loop
Step through a month in a sample office building. Figures are illustrative demo data, not customer results.
37 findings from 9 agents this month
Unpriced, unsorted- 06:12AHU-1 economizer at minimum position while outdoor air is 9.4 °CFree cooling maximizer
- 06:40Chiller 1 running at 18% load with free cooling availableChiller plant monitor
- 02:05AHU-3 supply airflow at 80% with zero presence detectedNighttime ventilation saver
- 04:30Heating start 2 h 10 min before occupancyNight setback optimizer
- 11:20Primary return temperature 6 °C above contract limitDistrict heating return guard
- 15:02AHU-2 filter pressure drop coefficient up 38% in 30 daysFilter analyzer
+ 31 more. Several describe the same root cause from different angles.
5 issues worth €43,900 a year
37 findings merged into 5 root causes- Free cooling unused on AHU-1, chillers running in spring€18,400/yrFrom: free cooling maximizer, chiller monitor Technician
- Ventilation running through unoccupied nights and weekends€11,200/yrFrom: nighttime ventilation saver Automatic
- District heating return temperature above contract limit€7,400/yrFrom: district heating return guard Capex plan
- Heating starts more than 2 hours before occupancy€5,300/yrFrom: night setback optimizer Automatic
- AHU-2 supply filter clogged, fan working harder€1,600/yrFrom: filter analyzer Technician
Each issue goes to whoever can fix it
Automatic
€16,500/yrMove heating start from 04:30 to 06:40 via the night setback optimizer.
Apply an occupancy-based weekend schedule to AHU-1 and AHU-3.
Technician
€20,000/yrSO-2214 · Check AHU-1 economizer damper actuator. Attached: trend log, expected €18,400/yr.
SO-2215 · Replace AHU-2 supply filter, bundled with the next visit.
Sent to the service provider’s queueCapex plan
€7,400/yrDistrict heating substation heat exchanger fouled. Sent to the ECM packager for next year’s renovation package.
Appears in the asset manager’s capex viewExpected vs measured, 60 days later
Weather- and occupancy-normalized-
Heating start moved to 06:40VerifiedExpected€5,300Measured€4,900
-
Weekend ventilation scheduleVerifiedExpected€11,200Measured€10,600
-
AHU-1 economizer actuator repairedCollecting data · 14 days leftExpected€18,400Measured—
What each role gets from it
Asset managers
Higher NOI, Taxonomy alignment protected, and a ranked list of which buildings need capex next year.
Property managers
Lower operating costs without new tenant complaints, since comfort agents check every change.
Technical operations
Fewer alarms, and work orders that arrive with the trend data and the reason they matter.
Sustainability leads
Verified savings that flow straight into ISO 50001, CSRD and GHG reporting.
Built on the agents you already run
The energy optimization agent doesn’t replace your monitoring agents. It sits on top of them and turns what they find into action.
Finds from
- Free cooling maximizer
- Nighttime ventilation saver
- District heating return guard
- Chiller plant efficiency monitor
- HVAC setpoint deviation checker
- Supply air filter analyzer
- ASHRAE Level I screening
Acts through
- Night setback optimizer
- Peak shaving agent
- Valve exerciser
- Service object consolidator
Reports to
- ISO 50001 EnPI tracker
- EU Taxonomy tracker
- BeLok ECM packager
- GHG climate auditor
See what your buildings are leaving on the table